Customization: | Available |
---|---|
Classification: | Imaging Diagnostic Equipment |
Type: | Ultrasound Scanner |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Dynamic range | 0- 100% ,5% step |
SpeckleReduction | 8 levels(0-7) |
ScanDensity | H ,M ,L |
Gain | 0~100 % ,2% step |
TGC | eight TGC controls |
FrameAverage | 8 levels(0-7) |
LineAverage | 8 levels(0-7) |
Edge Enhance | 8 levels(0-7) |
Gray Maps | 15 types(0- 14) |
Pseudocolor Maps | 7 types(0-6) |
Thermal Index | TIC,TIS,TIB |
2B, 4B formats | / |
Invert (U/ D) and transposed (L/ R) | / |
Focus Number | 4 |
Focus Depth | 16 levels (depth and probe dependent) |
FOV | 5 levels |
Image depth up to 35 cm in 0.5~4cm increments (depth dependent) | |
Phase inversion harmonic imaging technique is available for all probes |
Frequency | 2 levels |
Gain | 0~100% ,2% steps |
Wall filter | 8 levels(0-7) |
Sensitivity | H, M, L |
Flow | H, M, L |
Packet Size1 | 5 levels(0-4) |
FrameAverage | 8 levels(0-7) |
PostProc | 4 levels(0-3) |
Invert | On/Off |
Baseline | 7 levels(0-6) |
Color Maps | 4 levels(0-3) |
Color/PDI Width | 10%- 100%, 10% |
Color/PDI Height | 0.5-30cm(probe dependent) |
Color/PDI Center Depth | 1- 16cm(probe dependent) |
Steer | +/- 12°,7°(linear probe) |
Frequency | 2 levels |
Gain | 0~100% ,2% steps |
Wall filter | 8 levels(0-7) |
Sensitivity | H, M, L |
Flow | H, M, L |
Packet Size1 | 5 levels(0-4) |
FrameAverage | 8 levels(0-7) |
PostProc | 4 levels(0-3) |
Invert | On/Off |
Baseline | 7 levels(0-6) |
PDI Maps | 2 levels(0- 1) |
Color/PDI Width | 10%- 100%, 10% |
Color/PDI Height | 0.5-30cm(probe dependent) |
Color/PDI Center Depth | 1- 16cm(probe dependent) |
Steer | +/- 12°, +/-7°(linear probe) |
Frequency | 2 levels |
Sweep speed | 5 levels(0-4) |
Scale | 16 levels(0- 15) (depth and probe dependent) |
Scale Unit | cm/s,KHz |
Smooth | 8 levels(0-7) |
Pseudocolor Maps | 7 types(0-6) |
Dynamic range | 24- 100, 2 step |
Gain | 0- 100%, 2% step |
Wall filter | 4 levels(0-3) |
Dynamic range | 24- 100, 2 step |
Gain | 0- 100%, 2% step |
Wall filter | 4 levels(0-3) |
Angle correction | -89+89, 1 step |
Gate size | 8 levels(0-7mm) |
Wall filter | 5 levels(0-4) |
Invert | On/Off |
Baseline | 7 levels |
Real-time auto Doppler trace: maximum velocity, mean velocity |
Frequency | Up to 3 fundamental and 2 harmonic imaging frequencies |
Edge enhance | 8 levels(0-7) |
Dynamic range | 0- 100%,step 5% |
Gain | 0- 100 ,step 2 |
Gray Maps | 15 levels(0- 14) |
Pseudocolor Maps | 7 (0-6) |