• Reusable Handheld Pediatric Pulse Oximeter Sensor
  • Reusable Handheld Pediatric Pulse Oximeter Sensor

Reusable Handheld Pediatric Pulse Oximeter Sensor

Classification: Pulse Oximeter
Type: Pulse Oximeter
Certification: CE, ISO13485
Group: All
MOQ: 1PC
Brand: Howell
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Trading Company
  • Overview
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
HE-60C
Function
Pulse Oximeter
Power Supply Requirement
3.6 V DC 2V DC
Transport Package
Carton
Specification
100kg
Trademark
Howell
Origin
China
Production Capacity
5000set/Month

Product Description

 
Handheld Pulse Oximeter Reusable Adult SpO2 Sensor
Features

Operation of the product is simple and convenient.

The product is small in olume,light in weight and convenient in carrying.

Low power consumption.

Main performance

SpO2 value display

Pulse rate value display,bar graph display

Pulse waveform display

Low-voltage indication:low-voltage indicator appears before working abnormally which is due to low-voltag

The display mode can be changed

Screen brightness can be changed

Pulse sound indication

With alarm function

With SpO2 value and pulse rate value record function,the stored data can be uploaded to computer

.It can be connected with an external oximeter probe

.Real-time data can be transmitted to computer

Wireless transmission funnction only for CMS60CW)

Technical

SpO2 Measuring

Measure range:(%~100%

Accuracy:

When the SpO2 measure range is 70%~100%,the permission of absolute error is±2%:below 70%unspecified

Measurement of pulse rate

Measure range:30bpm-250bpm

Accuracy:±2 bpm or±2%(select larger)

Resolution

SpO2:1%.Pulse rate:1bpm.

Measurement Performance in Weak Filling Condition

SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%.

SpO2 error is±4%,pulse rate error is±2 bpm or±2%select larger).

Resistance to surrounding light

The deviation between the value measured in the condition of man-made lightor indoor natural light and that of darkroom is less than t1%.

Power supply requirement:3.6 V DC .2V DC.

Optical Sensor

Red light (wavelength is 660nm.6.65mW)

Infrared (wavelength is 880nm,6.75mW)
Adjustable alarm range

SpO2:0%100%

Pulse Rate:(bpm~254bpm
 
 
 
MOQ 1SET
 
Reusable Handheld Pediatric Pulse Oximeter SensorReusable Handheld Pediatric Pulse Oximeter SensorReusable Handheld Pediatric Pulse Oximeter SensorReusable Handheld Pediatric Pulse Oximeter Sensor
 
 
 
Certifications

Reusable Handheld Pediatric Pulse Oximeter SensorReusable Handheld Pediatric Pulse Oximeter SensorReusable Handheld Pediatric Pulse Oximeter SensorReusable Handheld Pediatric Pulse Oximeter Sensor

Company Profile

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now