|
Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Classification: | Imaging Diagnostic Equipment |
| Type: | Ultrasound Scanner |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Dynamic range | 0- 100% ,5% step |
| SpeckleReduction | 8 levels(0-7) |
| ScanDensity | H,M,L |
| Gain | 0~100 % ,2% step |
| TGC | eight TGC controls |
| FrameAverage | 8 levels(0-7) |
| LineAverage | 8 levels(0-7) |
| Edge Enhance | 8 levels(0-7) |
| Gray Maps | 15 types(0- 14) |
| Pseudocolor Maps | 7 types(0-6) |
| Thermal Index | TIC,TIS,TIB |
| 2B, 4B formats | / |
| Invert (U/ D) and transposed (L/ R) | / |
| Focus Number | 4 |
| Focus Depth | 16 levels (depth and probe dependent) |
| FOV | 5 levels |
| Image depth up to 35 cm in 0.5~4cm increments (depth dependent) | |
| Phase inversion harmonic imaging technique is available for all probes | |
| Frequency | 2 levels |
| Gain | 0~100% ,2% steps |
| Wall filter | 8 levels(0-7) |
| Sensitivity | H, M, L |
| Flow | H, M, L |
| Packet Size1 | 5 levels(0-4) |
| FrameAverage | 8 levels(0-7) |
| PostProc | 4 levels(0-3) |
| Invert | On/Off |
| Baseline | 7 levels(0-6) |
| Color Maps | 4 levels(0-3) |
| Color/PDI Width | 10%- 100%, 10% |
| Color/PDI Height | 0.5-30cm(probe dependent) |
| Color/PDI Center Depth | 1- 16cm(probe dependent) |
| Steer | +/- 12°,7°(linear probe) |
| Frequency | 2 levels |
| Gain | 0~100% ,2% steps |
| Wall filter | 8 levels(0-7) |
| Sensitivity | H, M, L |
| Flow | H, M, L |
| Packet Size1 | 5 levels(0-4) |
| FrameAverage | 8 levels(0-7) |
| PostProc | 4 levels(0-3) |
| Invert | On/Off |
| Baseline | 7 levels(0-6) |
| PDI Maps | 2 levels(0- 1) |
| Color/PDI Width | 10%- 100%, 10% |
| Color/PDI Height | 0.5-30cm(probe dependent) |
| Color/PDI Center Depth | 1- 16cm(probe dependent) |
| Steer | +/- 12°, +/-7°(linear probe) |
| Frequency | 2 levels |
| Sweep speed | 5 levels(0-4) |
| Scale | 16 levels(0- 15) (depth and probe dependent) |
| Scale Unit | cm/s,KHz |
| Smooth | 8 levels(0-7) |
| Pseudocolor Maps | 7 types(0-6) |
| Dynamic range | 24- 100, 2 step |
| Gain | 0- 100%, 2% step |
| Wall filter | 4 levels(0-3) |
| Dynamic range | 24- 100, 2 step |
| Gain | 0- 100%, 2% step |
| Wall filter | 4 levels(0-3) |
| Angle correction | -89+89, 1 step |
| Gate size | 8 levels(0-7mm) |
| Wall filter | 5 levels(0-4) |
| Invert | On/Off |
| Baseline | 7 levels |
| Real-time auto Doppler trace: maximum velocity, mean velocity | |
| Frequency | Up to 3 fundamental and 2 harmonic imaging frequencies |
| Edge enhance | 8 levels(0-7) |
| Dynamic range | 0- 100%,step 5% |
| Gain | 0- 100 ,step 2 |
| Gray Maps | 15 levels(0- 14) |
| Pseudocolor Maps | 7 (0-6) |
| Sweep speed | 5 levels(0-4) |